Power & Control Technology

Ekstrem fuktighet, varme, støy eller kulde – vi har løsninger for enhver applikasjonsutfordring. Fra skreddersydde systemløsninger til standard instrumenter. Erfaring, spesialkompetanse og innovasjon siden 1933.

Marine & Offshore Technology

Full serie med ekstremt robust og pålitelige løsninger – fra tavleinstrumentering til power management. Vi har testet, sertifisert, gitt support og ytt service siden 1933.

  • Generator Protection Unit – GPU-3

    The GPU-3 is a very flexible and compact protection unit suitable for both simple and extremely complex protection applications.

  • Generator Protection Unit – GPU-2

    Very flexible and marine-approved Generator Protection Unit with synchronisation. The GPU-2 contains all functions necessary to protect...

  • Multi-Differential Relay – MDR-2 – digital speed and accuracy, maximum reliability

    The MDR-2 is a differential current relay intended for protection of a generator against internal short circuits (leaking currents). It is based on a 16-bit digital signal processor...

  • Protective voltage relays – RMV-112D

    These uni-line protective voltage relays are applied for protection of generators, motors and transformers against adverse system voltage conditions...

  • Protective voltage relays – RMV-122D

    These uni-line protective voltage relays are applied for protection of generators, motors and transformers against adverse system voltage conditions...

  • Protective voltage relays – RMV-132D

    These uni-line protective voltage relays are applied for protection of generators, motors and transformers against adverse system voltage conditions...

  • Protective voltage relays – RMV-142D

    These uni-line protective voltage relays are applied for protection of generators, motors and transformers against adverse system voltage conditions...

  • Loss of excitation relay – RMQ-111D

    This uni-line relay is applied to protect a generator running in parallel with other generators from running as an induction generator due to underexcitation...

  • Overexcitation relay – RMQ-121D

    This uni-line relay is applied to protect a generator against overexcitation and will prevent it from generating too high currents in case of heavy inductive loads...

  • Overload relays – RMP-111D

    The protective overload relay uni-line RMP-111D forms part of a complete DEIF series of relays for protection and control of generators...

  • Overload/reverse power relay – RMP-112D

    The protective overload and reverse power relay uni-line RMP-112D forms part of a complete DEIF series of relays for protection and control of generators...

  • Reverse power relays – RMP-121D

    The protective reverse power relay uni-line RMP-121D forms part of a complete DEIF series of relays for protection and control of generators..

  • Frequency relay – RMF-112D

    The RMF-112D uni-line relay is applied for protection against underfrequency and overfrequency by supervising the frequency (of generators) in single-phase and 3-phase networks...

  • Short circuit relay – RMC-111D

    This short circuit uni-line relay is applied in cases where only protection against short circuit currents is required...

  • Short circuit current relay – RMC-121D

    This protective current relay forms part of a complete DEIF series of uni-line relays for protection and control of generators and is primarily designed for marine applications...

  • Short circuit and overcurrrent relay – RMC-122D

    This combined short circuit and overcurrent uni-line relay is applied for protection of generators against both overcurrents and short circuit currents...

  • Differential current relay – RMC-131D

    Differential current relays protect the generator against short circuits and leakage currents in the windings of the generator...

  • Double overcurrent relay – RMC-132D

    This double overcurrent uni-line relay is applied in cases where protection against overcurrents at two levels is required...

  • Stator earth fault relay – RMC-142D

    The stator earth fault uni-line relay protects the operators of the gen-set against electric shock as result of earth faults in the stator of the generator...

  • Loss of Mains Relay – LMR-111D

    The Loss of Mains Relay uni-line LMR-111D is for protection of the generator against damage resulting from a non-synchronised reconnection to the grid after a temporary mains failure...
     

  • Loss of Mains Relay – LMR-122D

    The Loss of Mains Relay uni-line LMR-122D is for protection of the generator against damage resulting from a non-synchronised reconnection to the grid after a temporary mains failure...

  • protection relay package - G59

    The mains decoupling uni-line relay - G59 package – forms part of a complete DEIF series of relays for the protection and control of generators...

Til toppen av siden