Changes:

  • 1- Update of self-check functionality

Ver. Dato Beskrivelse

2.50.3

13.04.2015

This software applies to the following DEIF products:

Multi-line 2 - BGC

Multi-line 2 - BGC-L

Changes:

  • 1- Update of self-check functionality

2.50.2

14.03.2013

Changes:

  • Start attempt settings was ignored.Corrected.
  • Minimum load in AMF was ignored.Corrected.

2.50.1

30.10.2012

  • The breaker did not open in Semi auto AMF mode. Only L1 decides if the frequency has dropped 0.5 Hz. Corrected.
  • The ramp down speed setting was ignored in Island mode and just ramped down as fast as possible. Corrected.
  • The genset stopped deloading and opened the breaker if it was 0.5 Hz over nominal settings. Corrected.

2.50.0

12.08.2010

New features:

  • VDO 3 can be used as temperature AND a Fuel sensor.

Changes:

  • Prompt for password when leaving block mode. Password level set in parameter 4901.
  • Ramp function implemented in Peak Shave mode.
  • Stop conditions in peak shaving improved.
  • VDO 2 calculations for level switch corrected.
  • MTU ADEC CAN communication improved.

2.40.2

17.10.2008

Improvement:

  • Stop command for Volvo and Scania engine communication changed

2.40.1

15.08.2008

  • Translations function corrected and max. number of languages reduced from 11 to 9

2.40.0

29.07.2008

New features:

  • Support of communication whit MTU-ADEC

Changes:

  • Volvo Penta EMS2 and SCANIA speed control updated.

2.31.3

12.12.2007

  • H2 option protocol now supports Modbus function 05 and 06.

2.31.2

29.10.2007

  • Password max limit changed to 32000.
  • Volvo Penta EMS2 preheat function updated.
  • Fire pump cooldown timer function updated.
  • M15 Analoge input measurements improved.

2.31.1

04.09.2007

  • Improved ramp up handling.
  • Volvo Penta EMS2 comm. error alarm updated.

2.31.0

19.06.2007

New features:

  • Regulation of reactive power, trough H2/H3

Changes:

  • Improved Ramp up delay handling.
  • Horn relay updated.
  • Improvement of external comm. enable input

2.30.3

16.01.2007

Changes:

  • Improved vector jump calculation.
  • BGC-L Input list updated

2.30.2

23.10.2006

Changes:

  • Handling of nominal power below 100kW updated.

2.30.1

28.09.2006

Changes:

  • GB handling updated.
  • IO view in util. SW updated.

2.30.0

05.09.2006

New features:

  • BGC-L for selected markets added.

Changes:

  • Frequency measurements >70Hz updated

2.21.2

26.06.2006

Changes:

  • GB operations adjusted upon back-sync-error.
  • Handling of MB close-failure updated.

2.21.1

08.03.2006

Changes:

  • Selection of Scania EMS 2 from USW updated.

2.21.0

24.02.2006

New features:

  • Scania EMS2 support added.

Changes:

  • Limit relay function updated.
  • Maximum frequency readout handling updated.
  • Volvo Penta EMS2 frequency change updated.
  • Power up sequence updated.

2.20.0

13.01.2006

New features:

  • Parallel enable added for Mains protections.
  • Channel 4800 (GOV / AVR relay setting) removed. Old relay settings was: GOV up: Relay 6, GOV down:
  • Relay 7, AVR up: Relay 8, AVR down: Relay 9.
  • Channel 4801-4804 added for GOV / AVR relay setting.
  • Auto start/stop input enabled in AMF.
  • Virtual input: Semi start, Semi MB off, Black busbar enable updated.
  • MLogic updated and new settings added.
  • Various Mlogic input / output added.
  • H5 Volvo Penta EMS 2 added.
  • Test mode setting: Simple, Full and Parallel.
  • Engine control relays configurable from MLogic when using Volvo Penta EMS 2
  • Self acknowledge added in USW. Channel 4452 "Auto reset warning FC" is removed.
  • Compact breaker handling added.
  • Manual control of GOV / AVR added for SEMI, TEST and AUTO.
  • DI alarms 1960-1990 added.
  • Actual language present in USW parameterlist.
  • Earth fault alarm and handling added.
  • Command timers output added to MLogic.
  • Selectable number of languages supported.
  • Service and master password settings available in JUMP menu.

Changes:

  • Overload 1 timer updated.
  • Horn function updated.
  • Gen-bar LED handling updated.
  • Short time parallel updated.
  • Semi mode handling updated.
  • Functionality of channel 2050 updated.
  • AVR reg. failure handling updated.
  • Mains fail handling updated.
  • MDEC protocol updated.
  • Scania protocol updated.
  • Back sync OFF functionality updated.
  • MB alarm updated.
  • Running detection updated.

2.12.2

28.11.2005

Changes:

  • MLogic command outputs updated.

2.12.1

17.11.2005

Changes:

  • Short time parallel updated
  • MLogic "MB synchronizing" updated
  • Minor updates

2.12.0

21.10.2005

New features:

  • Short time parallel added
  • VDE0108 sync. type updated

Changes:

  • Running, MB, GB offset updated
  • Password handling updated
  • Fuel pump logic/alarms updated
  • Short circuit precision updated
  • Hysterisys added to running detection
  • "Reset analogue input" functionality updated
  • M15 scaling added
  • FC updated on DI

2.11.1

30.06.2005

Changes:

  • Extended stop executed if running detection is lost

2.11.0

22.06.2005

New features:

  • MB trip failclass can be set in mains/bus protections
  • EIC alarms can be set to RUN activation

Changes:

  • GB trip stop failclass handling updated
  • Handling of overlap updated
  • Handling of view 3 updated

2.10.0

New features:

  • Support for MKIII PCB
  • Firepump cool down timer added
  • Delta V operation mode added

Changes:

  • Idle mode updated

På denne siden kan du laste ned programvare-oppdateringer til produktet/produktene dine og ta hjelp av forskjellige verktøy og tillegg som vil hjelpe deg med oppsett, med å oppdage feil og med å konfigurere produktet/produktene dine.

Vær oppmerksom på at ikke alle produktene våre kan oppdateres av brukeren. Det følger heller ikke med et verktøy for alle produktene våre. Derfor kan ikke listen på denne siden anses som en oversikt over produktprogrammet vårt.

DEIF vil registrere nedlastingen din samt e-postadressen som ble brukt for å sende ut informasjon om fremtidige oppdateringer dersom du ønsker det.

DEIF kan ikke holdes ansvarlig for eventuelle konsekvenser av mislykkede produktoppdateringer eller bruk av verktøy. DEIF A/S kan heller ikke holdes ansvarlig for konsekvenser forårsaket av endringer i oppførselen til produkter som et resultat av programvareoppgraderinger. Det er alltid brukerens ansvar å sikre korrekt oppsett og konfigurasjon før igangkjøring. Vennligst les igjennom versjonsloggen til programvaren før du oppdaterer produktet.

Lisensavtale for programvare lastet ned fra www.deif.com

Nedlastet programvare forblir DEIF sin eiendom. Programvaren kan ikke distribueres for kommersielle formål, endres eller gjenbrukes delvis eller i sin helhet eller selges til en tredjepart.

PRESSEMELDING, juni 2015

Produktforbedring spesielt knyttet til «eldre» DEIF A/S ML-2 produkter

På grunn av den høye kvaliteten, og dermed lange levetiden på DEIF produkter, har det totale antall «eldre» DEIF enheter i feltet økt gjennom årene. Gjennom DEIFs kontinuerlige fokus på produktkvalitet, produktytelse og tilbakemeldinger fra kunder – Også for de «gamle» produktene våre – Har vi funnet en mulig forbedring spesielt knyttet til kontrollenhetene våre: AGC-2, AGC-3, AGC-4, BGC-2 og MDR-2.

Den oppdaterte programvaren vil aktivere enheten for å utføre en «intern selvtest» ved å overvåke «helsetilstanden» til ulike hardware/software funksjoner. Interne problemer som oppdages vil utløse en alarm, basert på hvilke DEIF serviceavdeling som skal kontaktes.

I tillegg utvikler DEIF for tiden et verktøy til å håndtere konfigurasjonsfiler, noe som vil gjøre deg i stand til å enkelt kunne laste opp og lagre filer for senere re-konfigurasjon av enheter etter service, utilsiktede operatørendringer etc. Verktøyet vil gjøres tilgjengelig senere.

Som alltid, anbefaler vi at du installerer forbedringene våre for å kunne utnytte DEIF produktet ditt fullt ut.

All forbedret programvare kan gratis lastes ned på nytt på www.deif.com under «Programvare» og deretter « Programvarenedlasting».

Skulle du ha noen spørsmål eller om du skulle oppleve problemer med å finne relevant programvare til produktet ditt, kan du gjerne ringe DEIF A/S på +45 96149614 eller ditt relevante lokale DEIF kontor. Ellers er vi alltid klare til å hjelpe deg dersom du sender en e-post til support@deif.com.